293 lines
13 KiB
YAML
293 lines
13 KiB
YAML
groups:
|
|
- name: node_exporter_alerts
|
|
rules:
|
|
- alert: Node down
|
|
expr: up{job="monitoring-pi"} == 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
title: Node {{ $labels.instance }} is down
|
|
description: Failed to scrape {{ $labels.job }} on {{ $labels.instance }} for more than 2 minutes. Node seems down.
|
|
|
|
|
|
- alert: HostOutOfMemory
|
|
expr: node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host out of memory (instance {{ $labels.instance }})
|
|
description: Node memory is filling up (< 10% left)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostMemoryUnderMemoryPressure
|
|
expr: rate(node_vmstat_pgmajfault[1m]) > 1000
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host memory under memory pressure (instance {{ $labels.instance }})
|
|
description: The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}
|
|
|
|
- alert: HostUnusualNetworkThroughputIn
|
|
expr: sum by (instance) (rate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual network throughput in (instance {{ $labels.instance }})
|
|
description: Host network interfaces are probably receiving too much data (> 100 MB/s)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostUnusualNetworkThroughputOut
|
|
expr: sum by (instance) (rate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual network throughput out (instance {{ $labels.instance }})
|
|
description: Host network interfaces are probably sending too much data (> 100 MB/s)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostUnusualDiskReadRate
|
|
expr: sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual disk read rate (instance {{ $labels.instance }})
|
|
description: Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostUnusualDiskWriteRate
|
|
expr: sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual disk write rate (instance {{ $labels.instance }})
|
|
description: Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}
|
|
|
|
# Please add ignored mountpoints in node_exporter parameters like
|
|
# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)".
|
|
# Same rule using "node_filesystem_free_bytes" will fire when disk fills for non-root users.
|
|
- alert: HostOutOfDiskSpace
|
|
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host out of disk space (instance {{ $labels.instance }})
|
|
description: Disk is almost full (< 10% left)\n VALUE = {{ $value }}
|
|
|
|
# Please add ignored mountpoints in node_exporter parameters like
|
|
# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)".
|
|
# Same rule using "node_filesystem_free_bytes" will fire when disk fills for non-root users.
|
|
- alert: HostDiskWillFillIn24Hours
|
|
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host disk will fill in 24 hours (instance {{ $labels.instance }})
|
|
description: Filesystem is predicted to run out of space within the next 24 hours at current write rate\n VALUE = {{ $value }}
|
|
|
|
- alert: HostOutOfInodes
|
|
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint="/rootfs"} * 100 < 10 and ON (instance, device, mountpoint) node_filesystem_readonly{mountpoint="/rootfs"} == 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host out of inodes (instance {{ $labels.instance }})
|
|
description: Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostInodesWillFillIn24Hours
|
|
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint="/rootfs"} * 100 < 10 and predict_linear(node_filesystem_files_free{mountpoint="/rootfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly{mountpoint="/rootfs"} == 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host inodes will fill in 24 hours (instance {{ $labels.instance }})
|
|
description: Filesystem is predicted to run out of inodes within the next 24 hours at current write rate\n VALUE = {{ $value }}
|
|
|
|
- alert: HostUnusualDiskReadLatency
|
|
expr: rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual disk read latency (instance {{ $labels.instance }})
|
|
description: Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostUnusualDiskWriteLatency
|
|
expr: rate(node_disk_write_time_seconds_totali{device!~"mmcblk.+"}[1m]) / rate(node_disk_writes_completed_total{device!~"mmcblk.+"}[1m]) > 0.1 and rate(node_disk_writes_completed_total{device!~"mmcblk.+"}[1m]) > 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual disk write latency (instance {{ $labels.instance }})
|
|
description: Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostHighCpuLoad
|
|
expr: 100 - (avg by(instance) (rate(node_cpu_seconds_total{mode="idle"}[2m])) * 100) > 80
|
|
for: 0m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host high CPU load (instance {{ $labels.instance }})
|
|
description: CPU load is > 80%\n VALUE = {{ $value }}
|
|
|
|
- alert: HostCpuStealNoisyNeighbor
|
|
expr: avg by(instance) (rate(node_cpu_seconds_total{mode="steal"}[5m])) * 100 > 10
|
|
for: 0m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host CPU steal noisy neighbor (instance {{ $labels.instance }})
|
|
description: CPU steal is > 10%. A noisy neighbor is killing VM performances or a spot instance may be out of credit.\n VALUE = {{ $value }}
|
|
|
|
# 1000 context switches is an arbitrary number.
|
|
# Alert threshold depends on nature of application.
|
|
# Please read: https://github.com/samber/awesome-prometheus-alerts/issues/58
|
|
- alert: HostContextSwitching
|
|
expr: (rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 1000
|
|
for: 0m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host context switching (instance {{ $labels.instance }})
|
|
description: Context switching is growing on node (> 1000 / s)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostSwapIsFillingUp
|
|
expr: (1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host swap is filling up (instance {{ $labels.instance }})
|
|
description: Swap is filling up (>80%)\n VALUE = {{ $value }}
|
|
|
|
- alert: HostSystemdServiceCrashed
|
|
expr: node_systemd_unit_state{state="failed"} == 1
|
|
for: 0m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host SystemD service crashed (instance {{ $labels.instance }})
|
|
description: SystemD service crashed\n VALUE = {{ $value }}
|
|
|
|
- alert: HostPhysicalComponentTooHot
|
|
expr: node_hwmon_temp_celsius > 75
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host physical component too hot (instance {{ $labels.instance }})
|
|
description: Physical hardware component too hot\n VALUE = {{ $value }}
|
|
|
|
- alert: HostNodeOvertemperatureAlarm
|
|
expr: node_hwmon_temp_crit_alarm_celsius == 1
|
|
for: 0m
|
|
labels:
|
|
severity: critical
|
|
annotations:
|
|
summary: Host node overtemperature alarm (instance {{ $labels.instance }})
|
|
description: Physical node temperature alarm triggered\n VALUE = {{ $value }}
|
|
|
|
- alert: HostRaidArrayGotInactive
|
|
expr: node_md_state{state="inactive"} > 0
|
|
for: 0m
|
|
labels:
|
|
severity: critical
|
|
annotations:
|
|
summary: Host RAID array got inactive (instance {{ $labels.instance }})
|
|
description: RAID array {{ $labels.device }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostRaidDiskFailure
|
|
expr: node_md_disks{state="failed"} > 0
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host RAID disk failure (instance {{ $labels.instance }})
|
|
description: At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}
|
|
|
|
- alert: HostOomKillDetected
|
|
expr: increase(node_vmstat_oom_kill[1m]) > 0
|
|
for: 0m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host OOM kill detected (instance {{ $labels.instance }})
|
|
description: OOM kill detected\n VALUE = {{ $value }}
|
|
|
|
- alert: HostEdacCorrectableErrorsDetected
|
|
expr: increase(node_edac_correctable_errors_total[1m]) > 0
|
|
for: 0m
|
|
labels:
|
|
severity: info
|
|
annotations:
|
|
summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }})
|
|
description: Instance has had {{ printf "%.0f" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostEdacUncorrectableErrorsDetected
|
|
expr: node_edac_uncorrectable_errors_total > 0
|
|
for: 0m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})
|
|
description: Instance has had {{ printf "%.0f" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostNetworkReceiveErrors
|
|
expr: rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host Network Receive Errors (instance {{ $labels.instance }}:{{ $labels.device }})
|
|
description: Instance interface has encountered {{ printf "%.0f" $value }} receive errors in the last five minutes.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostNetworkTransmitErrors
|
|
expr: rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host Network Transmit Errors (instance {{ $labels.instance }}:{{ $labels.device }})
|
|
description: Instance has encountered {{ printf "%.0f" $value }} transmit errors in the last five minutes.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostNetworkInterfaceSaturated
|
|
expr: (rate(node_network_receive_bytes_total{device!~"^tap.*"}[1m]) + rate(node_network_transmit_bytes_total{device!~"^tap.*"}[1m])) / node_network_speed_bytes{device!~"^tap.*"} > 0.8
|
|
for: 1m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host Network Interface Saturated (instance {{ $labels.instance }}:{{ $labels.interface }})
|
|
description: The network interface is getting overloaded.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostConntrackLimit
|
|
expr: node_nf_conntrack_entries / node_nf_conntrack_entries_limit > 0.8
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host conntrack limit (instance {{ $labels.instance }})
|
|
description: The number of conntrack is approching limit\n VALUE = {{ $value }}
|
|
|
|
- alert: HostClockSkew
|
|
expr: (node_timex_offset_seconds > 0.05 and deriv(node_timex_offset_seconds[5m]) >= 0) or (node_timex_offset_seconds < -0.05 and deriv(node_timex_offset_seconds[5m]) <= 0)
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host clock skew (instance {{ $labels.instance }})
|
|
description: Clock skew detected. Clock is out of sync.\n VALUE = {{ $value }}
|
|
|
|
- alert: HostClockNotSynchronising
|
|
expr: min_over_time(node_timex_sync_status[1m]) == 0 and node_timex_maxerror_seconds >= 16
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host clock not synchronising (instance {{ $labels.instance }})
|
|
description: Clock not synchronising.\n VALUE = {{ $value }}
|
|
|